Communion Cup Mold

 

  Communion Cup Mold

 

Mold Type: This is a 8x8" manual mold.
Temperature: 200C at zone 1
Material: Natural FDA PP with White Dye
Additional Plates: None
Cavities: 8
Cycle Time: 60 seconds
Expected Output: 480 parts per hour, 400 with beaks

Notes:

  • Please read JY350-ST power on/off procedure first here.
  • Please read the JY-350-ST 8x8 automatic mold installation guide here.

This part is communion cup with a little bread side and a deeper part for the juice or wine.

Operation

This mold is fairly automatic and should eject the 8 communion cups after each shot.

Quality Checks

  1. Make sure the part is fully formed.
  2. Check that the part is flat and not warped.
  3. Remove any flashing or gate remains.

Machine Setup:

This data is inaccurate until we run the mold and get the actual injection molder settings.


PORCHESON   Mold Open/Close Set
MovMould 15.4 mm
Act Pres Flux Place
CLOF 90.0 0.0 110.0 mm
LOWP 60.0 0.0 40.0 mm
HIGP 45.00 0.0 1.00 s
Act Pres Flux Place
0. LOW 30.0 0.0 70.0 mm
0. FS 30.0 0.0 50.0 mm
0. SL 10.0 0.0 6.0 mm
Unloa 25.0 0.0 2.00 s
Slow Set
M.C.Pres 30.0 bar
M.C.Flux 0.0 %
M.O.Pres 20.0 bar
M.O.Flux 0.0 %
Low. P.T 30.00 S
LMT C/O T 30.00 S
Mach Hand Disable
Ejec. InMdCl 0.00

 

PORCHESON   INJ Set
Screw P: 54.95 mm
Act Pres Flux position
Inj1 50.0 0.0 65.00
Inj2 50.0 0.0 20.00
Inj3 20.0 0.0 15.00
Inj4 0.0 0.0 0.00
Inj5 0.0 0.0 0.00
Hold.Pr 40.0 0.0 0.00 S
Hold.Pr 0.0 0.0 0.00 S
Hold.Pr 0.0 0.0 0.00 S
INJ.T 6.00 S
INJ.Mode Location
Loct.Mode *****
InjCheck Disable
PmtError± 0.00 mm
InjCheckPos 0.00 mm

 

PORCHESON   Melt/Auto CI StuffSet
Screw P: 67.42 mm
Act Pres PrePress Flux Position
B. Tk 60.0
0.0 45.00
Melt3 100.0 0.0 0.0 42.00
Melt2 0.0 0.0 0.0 0.00
Melt1 0.0 0.0 0.0 0.00
F. Tk 0.0
0.0 0.00
MeltLmt 60.00 S
FirstCool 0.00 S
ThenCool 0.00 S
CoolStopM Disable
CI. StuffS Pres Flux Time
TaKe 44.0 0.0 1.00
Melt 55.0 0.0 1.00
Inje 35.0 0.0 1.00
Cl. Stuff Enable
Cl. Times 999

 

PORCHESON   NOZZ/EJECT SET
Act Pres Flux Time Place
NozzUp 10.0 0.0 1.00 ******
NozDown 5.0 0.0 1.00 ******
L. Keep 20.0 0.0 1.00 ******
L. EjcAdv 20.0 0.0 1.00 ******
L. EjcRet 5.0 0.0 1.00 ******
R. Keep 0.0 0.0 1.00 ******
R. EjcAdv 5.0 0.0 1.00 ******
R. EjcRet 5.0 0.0 1.00 ******
L. EjectPlac ****** mm
R. EjectPlac ****** mm

AutoNozRet Disable

EjectFunc Disable
EjectMode Times
Ejec. Times 1
EjecAdvDel 1.00 S
EjecRetDel 0.00 S

 

PORCHESON   Temp. Set

TempCurve Ejec 1Seg 2Seg 3Seg
Meas (°C) ***** % <temp> <temp> <temp>
Set (°C) ***** 190.0 220.0 220.0
Max (+) *** 75.0 75.0 75.0
Min (-) *** 75.0 75.0 75.0
Station **** Lower Lower Lower
Eje. Mode O.ring Scr. C. BT. T 2.00 S Galv
KeepWarm Disable Insulation valu *** °C

NOTES/HISTORY

  • 2026-07-09 - Created page to capture information